PROPERTY DIAGRAMS AND STEAM TABLES
Thermodynamics
Summary
The important information from this chapter is summarized below.
Property Diagrams and Steam Tables Summary
The Mollier diagram can be used to determine various properties of a fluid.
Mollier diagram is an h versus s plot.
Can only be used when quality is greater than 50% and for superheated
steam.
Contains a series of constant temperature, constant pressure, constant
moisture content, and constant superheat lines.
The steam tables can be used to determine various properties of water using the
following equations.
v = xvg + (1 - x)vf
h = xhg + (1 - x)hf
s = xsg + (1 - x)sf
x =
v
vf
vfg
x =
h
hf
hfg
x =
s
sf
sfg
The change in enthalpy of a fluid as it passes through a component can be
determined using a Mollier diagram on steam tables.
HT-01
Page 52
Rev. 0